No position light intensity may exceed the applicable values in the following table, except as provided in §25.1389(b)(3).
--------------------------------------------------------------
Maximum intensity
-----------------------
Overlaps Area A Area B
(candles) (candles)
--------------------------------------------------------------
Green in dihedral angle L............... 10 1
Red in dihedral angle R................. 10 1
Green in dihedral angle A............... 5 1
Red in dihedral angle A................. 5 1
Rear white in dihedral angle L.......... 5 1
Rear white in dihedral angle R.......... 5 1
--------------------------------------------------------------
Where --
(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10 degrees but less than 20 degrees; and
(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20 degrees.